
Product Catalogue

Temperature Controller KT-520
Home >> Prodcut Catalogue >> Controller for Freezing
| Temperature Controller KT-520 | |
| Brand Name: | Neutral or KingTill |
| Brief Info: | 5 Relays, Two NTC sensors, 2m (L) |
|
|
|
Product Description
Temperature controller KT-520
Function:
Temperature measuring and Control / Automatic defrost by electric heater or hot gas,
Light Control, Electric heater defog/ High and Low temperature alarm, Self Testing /Parameter Locking
Technical Parameter:
1. Power Supply: Output transformer 12VAC
2. Temperature sensor: NTC, two sensors, 2m (L)
3. Temp. measuring range: -45℃ ~ 150℃ Accuracy: ±1℃
4. Temp. controlling range: -45℃ ~ 50℃ Default : -18℃
5. Dimension: 142(L) × 38(W) × 35(D), Mounting Size: 137(L) × 31.5(W) mm
6. Operating environment: Temp: -10℃ ~ 60℃; Relative Humidity: 20%~90%(No condensing)
7. Relay output contact capacity:
Compressor: 30A/250VAC
Defog: 10A/250VAC
Evap. Fan: 5A/250VAC
Llight: 5A/250VAC
Defrost heater: 10A/250VAC
Menu:
| Parameter | Function | Set range | Default |
| E1 | Lower set-point limit | -45℃~Set temp. | -30℃ |
| E2 | Higher set-point limit | Set temp.~50℃ | 30℃ |
| E3 | Temp.Return Difference | 1~10℃ | 4℃ |
| E4 | Comp.start delay time | 0~10Min | 2Min |
| E5 | Room Temp. Calibration | -10~10℃ | 0 |
| E6 | Evap.Temp. Calibration | -10~10℃ | 0 |
| F0 | Defrost Mode | 0=Electric heater 1=Hot gas | 0 |
| F1 | Defrost Time | 1~60Min | 20Min |
| F2 | Defrost Cycle | 0~24Hr | 6Hr |
| F3 | Defrost termination temp. | 0~50~0℃ | 8℃ |
| F4 | Display during defrost |
0=Normal display 1=Last value before defrost |
0 |
| F5 | Dripping time after defrost | 0~10Min | 2Min |
| H1 | Fan start delay time | 0~10Min | 1Min |
| H2 | Fan operating function |
0=Parallel with comp. 1=Continuous running except defrost |
0 |
| H3 | Fan control during defrosting. | 0=always OFF 1=always ON | 0 |
| C2 | High temperature alarm | C3~130℃ | 40℃ |
| C3 | Low temperature alarm | -45℃~C2 | -40℃ |
| C4 | Alarm time delay | 1~90~1Min | 60Min |










