Temperature Controller KT-330
Home >> Prodcut Catalogue >> Controller for Freezing
Temperature Controller KT-330 | |
Brand Name: | Nuetral or KT Instrument |
Brief Info: | Range of temperature: -45~150℃, 3 relays, 2 sensors, NTC, 2m(L) |
Product Description
Temperature Controller: KT-330Temperature Display/ Temperature Control, Manual, automatic defrost by electric heater
Evap. Fan Control, Value Storing/ Self Testing /Parameter Locking,
Technical Parameter:
1. Output transformer: AC 12V(one transformer matched with one temp. controller)
2. Temperature sensor: NTC, 2 sensors (for cold room & defrost control), 2m(L)
3. Temperature measuring range:: -45~150℃(-45~150℉) Accuracy: ±1℃(±2℉)
4. Temperature controlling range: -45~45℃(-45~120℉) Default: -10℃(14℉)
5. Dimension: 77(Length) ×35(Width)×60(Depth)mm
Mounting hole dimension: 71(Length)×29(Width)mm
6. Operating environment: Temp. -10~60℃(14~140℉)
Relative Humidity: 20%~90%(Non-condensing)
7. Output contact capacity:
Compressor: N.O. 20A/250VAC (applicable to 1 HP compressor)
Defrost: N.O.10A/250VAC (applicable to 1KW load, if more it needs to connect an AC contactor)
Evap. Fan: N.O. 5A/250VAC
Menu:
Parameter | Function | Set range | Default |
PAS | Password | 00~99 | |
E1 | Lower setpoint limit | -45℃/45℉~Set temp. | -22℃/-8℉ |
E2 | Higher setpoint limit | Set temp.~45℃/120℉ | 10℃/50℉ |
E3 | Temp.hysteresis | 1~10℃/ 1~36℉ | 5℃/9℉ |
E4 | Comp.start delay time | 0~10Min | 2Min |
E5 | Offset on room Temp. | -20~20℃/℉ | 0 |
E6 | Offset on evap.Temp. | -20~20℃/℉ | 0 |
F1 | Max.Defrost duration | 1~60Min | 20Min |
F2 | Defrost interval time | 0~24Hr | 4Hr |
F3 | Defrost termination temp. | 0~20℃/ 32~68℉ | 12℃/54℉ |
F4 | Display during defrost |
0=Normal display 1=Last value before defrost |
1 |
F5 | Fan operating function |
0=Parallel with comp. 1=Continuous running except defrost 2=Evaporator temperature control |
0 |
F6 | Dripping time | 0~10Min | 2Min |
F7 | Fan delay start mode after defrost |
0=Time 1=Controlled by F9 |
1 |
F8 | Fan delay start time after defrost | 0~10Min | 2Min |
F9 |
Fan start temp. (Defrost sensor temp.) |
-30~30℃ -22~86℉ |
-4℃/25℉ |
C1 | Temperature unit | Celsius=℃ Fahr.=℉ | ℃ |
C2 | High temperature alarm | Set value~49℃/121℉~OFF | 40℃/104℉ |
C3 | Low temperature alarm | OFF~-44℃/-44℉~Set value | OFF |
C4 | Alarm time delay | 0~90Min | 30Min |